ACCULINK 3166 DSU/CSUUSER’S GUIDEDocument No. 3166-A2-GB20-10November 1998
Contents iv3166-A2-GB20-10November 1998A SDCP MenuB Technical Specifications Overview B-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SDCP Menu A-23166-A2-GB20-10November 1998This page intentionally left blank.
B-13166-A2-GB20-10November 1998Technical SpecificationsBOverviewThe technical specifications for the 3166 DSU/CSU are listed in Table B-1. Thefan mod
Technical Specifications B-23166-A2-GB20-10November 1998Table B-1. ACCULINK Model 3166 DSU/CSU Technical Specifications (2 of 2)Specifications Criteri
C-13166-A2-GB20-10November 1998Configuration OptionsCOverviewThe DSU/CSU configuration option tables contain a list of all configurationoptions and t
Configuration Options C-23166-A2-GB20-10November 1998Port Configuration OptionsTable C-1. Port Configuration Options (1 of 5)Port Type: E530 (Factory
Configuration Options C-33166-A2-GB20-10November 1998Table C-1. Port Configuration Options (2 of 5)Port LB: Disab (Factory 1) Both (Factory 2)Next
Configuration Options C-43166-A2-GB20-10November 1998Table C-1. Port Configuration Options (3 of 5)Tx Clock: IntNext Int Ext PrevData Port
Configuration Options C-53166-A2-GB20-10November 1998Table C-1. Port Configuration Options (4 of 5)Err Rate: 10E-4Next 10E-4 10E-5 10E-6
Configuration Options C-63166-A2-GB20-10November 1998Table C-1. Port Configuration Options (5 of 5)Far-end: DisabNext Disab Maint PrevFar-
Configuration Options C-73166-A2-GB20-10November 1998Network Interface Configuration OptionsTable C-2. Network Interface Configuration Options (1 of 3
Contents v3166-A2-GB20-10November 1998E SNMP MIB Objects Overview E-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Configuration Options C-83166-A2-GB20-10November 1998Table C-2. Network Interface Configuration Options (2 of 3)NET LLB: EnabNext Enab Disab
Configuration Options C-93166-A2-GB20-10November 1998Table C-2. Network Interface Configuration Options (3 of 3)Circuit Ident:Next Edit Clear
Configuration Options C-103166-A2-GB20-10November 1998Table C-3. General Configuration Options (2 of 2)TstDuration: 10Next Up Down Save
Configuration Options C-113166-A2-GB20-10November 1998Table C-4. User Interface Configuration Options (2 of 6)Com Use: ASCIINext Mgmt ASCII
Configuration Options C-123166-A2-GB20-10November 1998Table C-4. User Interface Configuration Options (3 of 6)ComConnected:Next Edit Clear
Configuration Options C-133166-A2-GB20-10November 1998Table C-4. User Interface Configuration Options (4 of 6)ComDisconnect:Next Edit Clear
Configuration Options C-143166-A2-GB20-10November 1998Table C-4. User Interface Configuration Options (5 of 6)Ignore DTR: NoNext Yes No Pr
Configuration Options C-153166-A2-GB20-10November 1998Table C-4. User Interface Configuration Options (6 of 6)TnDiscTm: 5Next Up Down Save
Configuration Options C-163166-A2-GB20-10November 1998Alarm Configuration OptionsTable C-5. Alarm Configuration Options (1 of 3)Alrm Msg: DisabNext
Configuration Options C-173166-A2-GB20-10November 1998Table C-5. Alarm Configuration Options (2 of 3)DialOut: DisabNext Enab Disab PrevAla
Contents vi3166-A2-GB20-10November 1998G Front Panel Emulation Overview G-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Configuration Options C-183166-A2-GB20-10November 1998Table C-5. Alarm Configuration Options (3 of 3)Err Rate: 10E-4Next 10E-4 10E-5 10E-6
Configuration Options C-193166-A2-GB20-10November 1998Management Configuration OptionsThe Management configuration options are divided into two tables
Configuration Options C-203166-A2-GB20-10November 1998Table C-6. General Management Configuration Options (2 of 4)NMS n Acs: ReadNext Read R/W
Configuration Options C-213166-A2-GB20-10November 1998Table C-6. General Management Configuration Options (3 of 4)Access 1: ReadNext Read R/W
Configuration Options C-223166-A2-GB20-10November 1998Table C-6. General Management Configuration Options (4 of 4)Com NetMask: Next Edit Clear
Configuration Options C-233166-A2-GB20-10November 1998Table C-7. Management Trap Configuration Options (1 of 2)Num Trap Mgrs: 1Next 1 2 3
Configuration Options C-243166-A2-GB20-10November 1998Table C-7. Management Trap Configuration Options (2 of 2)Entp Trap: EnabNext Enab Disab
D-13166-A2-GB20-10November 1998Pin AssignmentsDOverviewThe DSU/CSU is shipped with a power module and a VF cable. Various otherinterconnecting cables
Pin Assignments D-23166-A2-GB20-10November 1998Figure D-1. T1 Line Interface Cable, RJ48C-to-RJ48CFigure D-2. T1 Line Interface Cable, RJ48C-to-DA15P
Pin Assignments D-33166-A2-GB20-10November 1998EIA-530-A Port Interface ConnectorThe EIA-530-A Port interface connector information is shown in Table
vii3166-A2-GB20-10November 1998About This GuideDocument Purpose and Intended AudienceThis operator’s guide contains installation, operation, and main
Pin Assignments D-43166-A2-GB20-10November 1998EIA-530-A-to-RS449 Cable InterfaceThe EIA-530-A-to-RS449 adapter cable (Figure D-3) provides the RS449i
Pin Assignments D-53166-A2-GB20-10November 1998Table D-3. RS449 Cable InterfaceSignalCircuitMnemonicCCITTNumberDirection PinShield — — — 1Signal Groun
Pin Assignments D-63166-A2-GB20-10November 1998EIA-530-A-to-V.35 Cable InterfaceThe EIA-530-A-to-V.35 adapter cable (Figure D-4) provides the V.35 int
Pin Assignments D-73166-A2-GB20-10November 1998Table D-4. V.35 Cable InterfaceSignalCCITT Number Direction PinShield — — ASignal Common 102 — BTransmi
Pin Assignments D-83166-A2-GB20-10November 1998EIA-530-A-to-X.21 Cable InterfaceThe EIA-530-A-to-X.21 adapter cable (Figure D-5) provides the X.21 int
Pin Assignments D-93166-A2-GB20-10November 1998COM Port InterfaceThe COM port connects to a PC for front panel emulation, to an ASCII terminal orprint
Pin Assignments D-103166-A2-GB20-10November 1998Figure D-6. COM Port-to-PC CableFigure D-7. COM Port-to-Terminal/Printer Cable
Pin Assignments D-113166-A2-GB20-10November 1998COM Port to Modem CableUse a serial crossover cable when connecting the COM port to a modem or otherex
Pin Assignments D-123166-A2-GB20-10November 1998This page intentionally left blank.
E-13166-A2-GB20-10November 1998SNMP MIB ObjectsEOverviewThis appendix describes the Management Information Base (MIB) objects thatare supported by th
About This Guide viii3166-A2-GB20-10November 1998Section DescriptionAppendix ESNMP MIB Objects. Lists and describes the MIB supportprovided by the DSU
SNMP MIB Objects E-23166-A2-GB20-10November 1998MIB II (RFC 1213)The objects defined by MIB II are organized into 10 different groups. TheDSU/CSU impl
SNMP MIB Objects E-33166-A2-GB20-10November 1998System Group – “sysObjectID” Object (system 2)This object provides the authoritative identification of
SNMP MIB Objects E-43166-A2-GB20-10November 1998Interface Group – “ifIndex” Object (ifEntry 1)This object provides the index into the ifTable and typi
SNMP MIB Objects E-53166-A2-GB20-10November 1998Interface Group – “ifSpeed” Object (ifEntry 5)This object provides the interface’s current bandwidth i
SNMP MIB Objects E-63166-A2-GB20-10November 1998Interface Group – Input Counters (objects ifEntry 10 to ifEntry 15)These objects collect statistics on
SNMP MIB Objects E-73166-A2-GB20-10November 1998IP Group – “ipForwarding” Object (ip 1)This object specifies whether the unit is acting as an IP gatew
SNMP MIB Objects E-83166-A2-GB20-10November 1998The following objects are defaulted if not specified in the set PDU used to add aroute. ipRouteMetric
SNMP MIB Objects E-93166-A2-GB20-10November 1998IP Group – “ipRouteMetric2” Object (ipRouteEntry 4)The following values are displayed for the ipRouteM
SNMP MIB Objects E-103166-A2-GB20-10November 1998Transmission Group, MIB IIObjects in the transmission group are supported on the network interface, t
SNMP MIB Objects E-113166-A2-GB20-10November 1998Near End Group, DS1/E1 MIBThe DS1 Near End Group consists of the following four tables: DS1 Configur
About This Guide ix3166-A2-GB20-10November 1998Reference Documents AT&T Technical Reference 54016 AT&T Technical Reference 62411 ANSI T1.40
SNMP MIB Objects E-123166-A2-GB20-10November 1998Near End Group – “dsx1LoopbackConfig” Object (dsx1ConfigEntry 9)This object specifies the loopback st
SNMP MIB Objects E-133166-A2-GB20-10November 1998Near End Group – “dsx1TransmitClockSource” Object (dsx1ConfigEntry 12)This object specifies the timin
SNMP MIB Objects E-143166-A2-GB20-10November 1998Near End Group – The DS1 Interval Table Objects (dsx1IntervalEntry)The following DS1 interval table o
SNMP MIB Objects E-153166-A2-GB20-10November 1998DS1 Fractional Group, DS1/E1 MIBThe DS1 Fractional Group consists of the DS1 fractional table. This t
SNMP MIB Objects E-163166-A2-GB20-10November 1998General Port Table – “rs232PortType” Object (rs232PortEntry 2)This object is used to identify the por
SNMP MIB Objects E-173166-A2-GB20-10November 1998Asynchronous Port Table, “rs232AsyncPortStopBits”(rs232AsyncPortEntry 3)This object specifies the num
SNMP MIB Objects E-183166-A2-GB20-10November 1998Input Signal Table, RS-232-like MIBThis table contains entries for the input signals that can be dete
SNMP MIB Objects E-193166-A2-GB20-10November 1998Generic-Interface MIB Extensions (RFC 1229)This generic-interface MIB is an experimental MIB that pro
SNMP MIB Objects E-203166-A2-GB20-10November 1998 testSendV54Up – Sends a V54 up code to the remote unit. Only supportedfor the data ports. testSend
SNMP MIB Objects E-213166-A2-GB20-10November 1998Generic Interface Test Table – “ifExtnsTestCode” Object (ifExtnsTestEntry 6)This object contains a co
About This Guide x3166-A2-GB20-10November 1998This page intentionally left blank.
SNMP MIB Objects E-223166-A2-GB20-10November 1998Correlation between Menu Commands and SNMPObjectsTable E-1 provides a correlation between how a funct
SNMP MIB Objects E-233166-A2-GB20-10November 1998Table E-1. SNMP MIB to Front Panel Command Cross-Reference (2 of 4)Front Panel Command SNMP MIB Objec
SNMP MIB Objects E-243166-A2-GB20-10November 1998Table E-1. SNMP MIB to Front Panel Command Cross-Reference (3 of 4)Front Panel Command SNMP MIB Objec
SNMP MIB Objects E-253166-A2-GB20-10November 1998Table E-1. SNMP MIB to Front Panel Command Cross-Reference (4 of 4)Front Panel Command SNMP MIB Objec
SNMP MIB Objects E-263166-A2-GB20-10November 1998This page intentionally left blank.
F-13166-A2-GB20-10November 1998IP Networking Address ScenarioFOverviewThis appendix describes a means of configuring 31xx Series devices in anInterne
IP Networking Address Scenario F-23166-A2-GB20-10November 1998 The choice of a host address within a given subnet is completely arbitrary.Choose any
IP Networking Address Scenario F-33166-A2-GB20-10November 1998Scenario 2The second scenario (Figure F-2) is a carrier communicating with standalonerem
IP Networking Address Scenario F-43166-A2-GB20-10November 1998Scenario 3This third scenario (Figure F-3) shows a local carrier connected to remotecarr
IP Networking Address Scenario F-53166-A2-GB20-10November 1998Scenario 4An alternative addressing scheme, for the network is shown in Figure F-4. This
1-13166-A2-GB20-10November 1998Introduction1OverviewThe ACCULINKR 3166 DSU/CSU acts as an interface between the T1 digitalnetwork and the customer pr
IP Networking Address Scenario F-63166-A2-GB20-10November 1998Scenario 5Figure F-5 illustrates multiple COM ports on the same carrier connected todiff
G-13166-A2-GB20-10November 1998Front Panel EmulationGOverviewThe 3166 DSU/CSU offers functionality through Front Panel Emulation softwarethat is simi
Front Panel Emulation G-23166-A2-GB20-10November 1998 ProcedureTo install Front Panel Emulation software:1. Insert the diskette into the appropriate
Front Panel Emulation G-33166-A2-GB20-10November 1998Starting Front Panel EmulationIf the DSU/CSU selected is not locally attached to the PC, you must
Front Panel Emulation G-43166-A2-GB20-10November 19986. If you chose a Local destination, click on the Execute button. If you chose aRemote destinatio
H-13166-A2-GB20-10November 1998Asynchronous Terminal InterfaceOperationHOverviewYou can configure and manage the 3166 DSU/CSU from an asynchronouster
Asynchronous Terminal Interface Operation H-23166-A2-GB20-10November 1998Initiating an ATI SessionOnce the appropriate configuration option changes ha
Asynchronous Terminal Interface Operation H-33166-A2-GB20-10November 1998Menu OrganizationATI menus differ from SDCP menus in that they typically do n
Asynchronous Terminal Interface Operation H-43166-A2-GB20-10November 1998Using ATI Screens There are three types of ATI screens. Menu screens list s
Asynchronous Terminal Interface Operation H-53166-A2-GB20-10November 1998Table H-2. Keyboard KeysKeyboard KeyUsageCtrl-a Moves the cursor between the
Introduction 1-23166-A2-GB20-10November 1998Alarm Message CapabilityThe DSU/CSU can be attached, either locally or remotely, to an ASCII terminal orpr
Asynchronous Terminal Interface Operation H-63166-A2-GB20-10November 1998Setting Customer IdentificationThe customer identification is used to uniquel
Asynchronous Terminal Interface Operation H-73166-A2-GB20-10November 1998Displaying LED ConditionsThe same conditions monitored by the front panel LED
Asynchronous Terminal Interface Operation H-83166-A2-GB20-10November 1998Changing Configuration OptionsUse the Configuration branch of the main menu t
Asynchronous Terminal Interface Operation H-93166-A2-GB20-10November 19982. From the Load Configuration From screen, select a configuration option set
Asynchronous Terminal Interface Operation H-103166-A2-GB20-10November 1998Saving Edit ChangesProcedureTo save edit changes:1. From the last edit scre
Asynchronous Terminal Interface Operation H-113166-A2-GB20-10November 1998Establishing Access Security on a PortAlthough the password feature is avail
Asynchronous Terminal Interface Operation H-123166-A2-GB20-10November 1998Setting a PasswordIn addition to establishing access security on a port (ref
Asynchronous Terminal Interface Operation H-133166-A2-GB20-10November 1998Entering a Password to Gain AccessWhen access security is required, the Logi
Asynchronous Terminal Interface Operation H-143166-A2-GB20-10November 1998This page intentionally left blank.
I-13166-A2-GB20-10November 1998Equipment ListIEquipment Feature NumberModel 3166 DSU/CSU 3166-B3-010Front Panel Emulation Software 3100-C1-010T1 Line
Introduction 1-33166-A2-GB20-10November 1998Physical DescriptionThe Model 3166 DSU/CSU consists of a circuit card with front panel, and a rearconnecto
Equipment List I-23166-A2-GB20-10November 1998This page intentionally left blank.
GL-13166-A2-GB20-10November 1998GlossaryA test pattern consisting of a one (1) followed by seven zeros (on the network only).A rack-mounted device con
GlossaryGL-23166-A2-GB20-10November 1998An 8-slot backplane that fit over one half of the open section of the 3000 Series Carrier.This is a passive as
GlossaryGL-33166-A2-GB20-10November 1998Communications port. A computer’s serial communications port used to transmit to andreceive data from a modem.
GlossaryGL-43166-A2-GB20-10November 1998A thin, flexible magnetic disk enclosed in a protective jacket.Download branch of the DSU/CSU menu tree.A proc
GlossaryGL-53166-A2-GB20-10November 1998End of Number.A discrepancy between a measured or computed value or condition and the true orspecified value o
GlossaryGL-63166-A2-GB20-10November 1998Internet Protocol address. The address assigned to an internet host.International Standards Organization.Inter
GlossaryGL-73166-A2-GB20-10November 1998A compact assembly functioning as a component in a larger system or unit.Maximum Request Unit.A configuration
GlossaryGL-83166-A2-GB20-10November 1998A measure of the number of ones (marks, pulses) in relation to the total number of bitstransmitted.Quasi-Rando
GlossaryGL-93166-A2-GB20-10November 1998Serial Line Internet Protocol. Protocol for serial operation on an internet.Simple Network Management Protocol
Printed on recycled paper A3166-A2-GB20-10November 1998Copyright 1998 Paradyne Corporation.All rights reserved.Printed in U.S.A.NoticeThis publicati
Introduction 1-43166-A2-GB20-10November 1998This page intentionally left blank.
GlossaryGL-103166-A2-GB20-10November 1998Volts direct current.Voice Frequency. The part of the audio frequency range used to transmit voice sound(usua
IN-13166-A2-GB20-10 November 1998IndexAabortlamp test, 4-31loopback, 4-25test patterns, 4-28ACAMI method of channel allocation, 3-31Access, Commun
IndexIN-23166-A2-GB20-10November 1998configuration optionsprocedure for changing, 3-11tablesAlarm, C-16General, C-9Network Interface, C-7Port, C-
IndexIN-33166-A2-GB20-10 November 1998GGen (General) Configuration branchexample of use, 3-34option table, C-9IID (Identity) branch, example of use,
IndexIN-43166-A2-GB20-10November 1998network interfaceconfiguration options, C-7failure message, 4-2front panel LED indications, 3-5functional desc
IndexIN-53166-A2-GB20-10 November 1998Shared Diagnostic Control Panel (SDCP),acquiring/releasing the user interface, 3-38SNMP (Simple Network Managem
IndexIN-63166-A2-GB20-10November 1998VV.35 interface, D-7V.54 Loop 2. See data channel loopback (DCLB)V.54 Loop 3. See data terminal loopback (DTLB)W
496-15104 2-13166-A2-GB20-10November 1998Installation2Important InstructionsRead and follow all warning notices and instructions marked on the DSU/CSU
Installation 2-23166-A2-GB20-10November 1998Installation ProcedureTo install the DSU and rear connector module:1. At the rear of the carrier, set the
Installation 2-33166-A2-GB20-10November 19983. Using a Phillips screwdriver, loosen the screw holding the circuit pack lockand rotate the lock to the
Installation 2-43166-A2-GB20-10November 19987. Attach a modular cable (not included) to the COM connector of the rearconnector module. (See Appendix D
Installation 2-53166-A2-GB20-10November 19989. Attach the network cable to the NET connector on the rear connector module.Connect the other end of the
Installation 2-63166-A2-GB20-10November 1998The power-up self-test begins when power is applied. During the power-upself-test, the Fail LED flashes, t
3-13166-A2-GB20-10November 1998SDCP Operation3OverviewThis chapter contains information for operating your DSU/CSU using the optionalShared Diagnosti
SDCP Operation 3-23166-A2-GB20-10November 1998LCDThe LCD is used to display two types of data: Messages such as alarms, command/test completion, and
SDCP Operation 3-33166-A2-GB20-10November 1998Use the Function (F1, F2, F3) keys to make selections from the choicespresented on the second line of th
Important Information B3166-A2-GB20-10 November 1998Important Safety Instructions1. Read and follow all warning notices and instructions marked on the
98-16081bSystemLEDsNETDSU/CSU3166Port1OKFailTestSigOOFAlrmEERDTRTXDRXDCTSRTSSelectInOutNetMonSDCP Operation 3-43166-A2-GB20-10November 1998LEDsThere a
98-16081cNetworkInterfaceLEDsNETDSU/CSU3166Port1OKFailTestSigOOFAlrmEERDTRTXDRXDCTSRTSSelectInOutNetMonSDCP Operation 3-53166-A2-GB20-10November 1998T
98-16081aDataPortLEDsNETDSU/CSU3166Port1OKFailTestSigOOFAlrmEERDTRTXDRXDCTSRTSSelectInOutNetMonSDCP Operation 3-63166-A2-GB20-10November 1998Table 3-3
SDCP Operation 3-73166-A2-GB20-10November 1998Displaying Unit IdentityThe identity of the DSU/CSU (serial number, model number, software revisionlevel
SDCP Operation 3-83166-A2-GB20-10November 1998F1Identity:Cust ID=xxxxxxxxF2F3F1Identity:SRev=xx.xx.xxF2F3F1Identity:CCA1=xxxx-xxxF2F3
SDCP Operation 3-93166-A2-GB20-10November 1998Setting Customer IdentificationThe customer identification is the only identity number you can change. I
SDCP Operation 3-103166-A2-GB20-10November 1998Displaying LED ConditionsThe same conditions monitored by the front panel LEDs can also be monitoredby
SDCP Operation 3-113166-A2-GB20-10November 1998If you chose Prt1, the Port 1 LEDs screen lists the LED signals, two at a time,on the second line. A ve
SDCP Operation 3-123166-A2-GB20-10November 1998The configuration options are divided into functional groups. Appendix C containsa list of the configur
SDCP Operation 3-133166-A2-GB20-10November 1998Displaying/Editing Configuration OptionsProcedureTo display/edit configuration options:1. From the top
Important Information C3166-A2-GB20-10November 1998EMI Warnings!WARNING:This equipment has been tested and found to comply with the limits for a Class
SDCP Operation 3-143166-A2-GB20-10November 1998The configuration options for the selected functional group appear on theSDCP one option at a time. The
SDCP Operation 3-153166-A2-GB20-10November 1998Saving Edit ChangesSave edit changes to the Active area when you want those changes to take effectimmed
SDCP Operation 3-163166-A2-GB20-10November 1998Enabling the Communication PortCommunication between the 3166 DSU/CSU and an external PC, ASCII device,
SDCP Operation 3-173166-A2-GB20-10November 1998The set of valid characters for control of the carrier external COM port device isas follows: The numb
SDCP Operation 3-183166-A2-GB20-10November 1998Table 3-4. Control SequenceSequenceASCII HEX^A or ^a SOH 0x01^B or ^b STX 0x02^C or ^c ETX 0x03^D or ^d
SDCP Operation 3-193166-A2-GB20-10November 1998Configuring the DSU/CSU for SNMP or TelnetAccessTo configure the DSU/CSU for SNMP or Telnet access: En
SDCP Operation 3-203166-A2-GB20-10November 1998Selecting the PortThe SNMP manager, Telnet device, external LAN adapter, or network device(e.g., a rout
SDCP Operation 3-213166-A2-GB20-10November 1998Setting the IP AddressThe IP address is the address used by the SNMP or Telnet system to access theDSU/
SDCP Operation 3-223166-A2-GB20-10November 1998NOTE:Steps 8 and 9 describe the process for entering an IP address. Thisprocess applies to any IP addre
SDCP Operation 3-233166-A2-GB20-10November 1998Selecting the Link Layer ProtocolTwo link layer protocols, Point-to-Point Protocol (PPP) and Serial Lin
Important Information D3166-A2-GB20-10 November 1998Government Requirements and Equipment ReturnCertain governments require that instructions pertaini
SDCP Operation 3-243166-A2-GB20-10November 19985. Select Mgmt.F1Edit:User Alarm MgmtF2F36. From the Mgmt Config screen, select Gen.F1Mgmt Config:Gen T
SDCP Operation 3-253166-A2-GB20-10November 19985. Select Mgmt.F1Edit:User Alarm MgmtF2F36. From the Mgmt Config screen, select Gen.F1Mgmt Config:Gen T
SDCP Operation 3-263166-A2-GB20-10November 199812. Press F2 (Read) or F3 (R/W).F1Access 1:Next Read R/WF2F3The Read selection allows read-only access
SDCP Operation 3-273166-A2-GB20-10November 19987. Press F2 (Enab) to enable trap messages over the SNMP management link.F1SNMP Trap:Next Enab DisabF2F
SDCP Operation 3-283166-A2-GB20-10November 1998Configuring a Destination for SNMP TrapsA destination must be configured for each SNMP trap manager spe
SDCP Operation 3-293166-A2-GB20-10November 1998Allocating Data PortsBy using the configuration options, assign a specific port to DS0 channels on then
SDCP Operation 3-303166-A2-GB20-10November 1998 ProcedureTo select the data port:1. From the top-level menu screen, select Cnfig.2. Select the config
SDCP Operation 3-313166-A2-GB20-10November 1998Block or ACAMI Assignment MethodThe Assign By configuration option screen appears after you select a po
SDCP Operation 3-323166-A2-GB20-10November 19984. The Start At screen displays the configuration option used to select thestarting DS0 channel. The ne
SDCP Operation 3-333166-A2-GB20-10November 19984. Line 1 displays the 24 channels for the network interface. Line 2 displayswhat is allocated to the D
Important Information E3166-A2-GB20-10November 1998CanadaNOTICE TO USERS OF THE CANADIAN TELEPHONE NETWORKThe Industry Canada label identifies certifi
SDCP Operation 3-343166-A2-GB20-10November 1998Selecting the Timing SourceThe DSU/CSU provides the ability to select a master clock (timing) source th
SDCP Operation 3-353166-A2-GB20-10November 1998Establishing Access Security on the COM PortAlthough the password feature is available, it is not requi
SDCP Operation 3-363166-A2-GB20-10November 1998Setting a PasswordIn addition to establishing access security on a port (refer to the previous section,
SDCP Operation 3-373166-A2-GB20-10November 1998Entering a Password to Gain AccessYou are prompted to enter a password (up to 8 characters) when you ar
SDCP Operation 3-383166-A2-GB20-10November 1998Acquiring/Releasing the User InterfaceYou can access the user interface from either the the COM port or
SDCP Operation 3-393166-A2-GB20-10November 1998The inactive interface displays an interface idle message after control has beenreleased from the previ
SDCP Operation 3-403166-A2-GB20-10November 1998Resetting the DSU/CSUUse the Reset command to perform a power-on reset of the DSU/CSU. ProcedureTo res
4-13166-A2-GB20-10November 1998Monitoring and Testing4OverviewThe 3166 DSU/CSU can detect and report faults, and perform diagnostic tests.These featu
Monitoring and Testing 4-23166-A2-GB20-10November 19983. View the results of the last power-up self-test. If no problems were foundduring power-up, th
Monitoring and Testing 4-33166-A2-GB20-10November 1998Device Health and StatusUse the Device Health and Status branch to view the current health and s
i3166-A2-GB20-10November 1998ContentsAbout This Guide Document Purpose and Intended Audience vii. . . . . . . . . . . . . . . . . . . . . . . . .
Monitoring and Testing 4-43166-A2-GB20-10November 1998Table 4-2. Device Health and Status MessagesMessageDescriptionLOS at Net A Loss Of Signal condit
Monitoring and Testing 4-53166-A2-GB20-10November 1998Performance ReportsWhen the network interface is configured for ESF operation, networkperformanc
Monitoring and Testing 4-63166-A2-GB20-10November 19984. From the User Registers screen:— Press F1 to view current registers (go to Step 5)— Press F2
Monitoring and Testing 4-73166-A2-GB20-10November 19989. When you have selected the number of the interval you want to display, pressF3 (Dsply) to dis
Monitoring and Testing 4-83166-A2-GB20-10November 1998Table 4-3. Performance Registers (2 of 3)Register Totals DescriptionInterval DescriptionSES The
Monitoring and Testing 4-93166-A2-GB20-10November 1998Table 4-3. Performance Registers (3 of 3)Register Totals DescriptionInterval DescriptionStEvnt(O
Monitoring and Testing 4-103166-A2-GB20-10November 1998Resetting Performance RegistersYou can reset the performance registers via the ClrReg command i
Monitoring and Testing 4-113166-A2-GB20-10November 1998AlarmsThe DSU/CSU can be attached, either locally or remotely, to an ASCII terminal orprinter t
Monitoring and Testing 4-123166-A2-GB20-10November 1998SNMP TrapsSNMP traps are unsolicited messages that are sent from the DSU/CSU to anSNMP manager
Monitoring and Testing 4-133166-A2-GB20-10November 1998Table 4-4. Enterprise-Specific Trap DefinitionsTrap ValueEvententerpriseClockFail(1) The curren
Contents ii3166-A2-GB20-10November 19983 SDCP Operation Overview 3-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Monitoring and Testing 4-143166-A2-GB20-10November 1998TroubleshootingThe DSU/CSU is designed to provide you with trouble-free service. However,Table
Monitoring and Testing 4-153166-A2-GB20-10November 1998Table 4-6. Troubleshooting (2 of 2)Symptom SolutionsPossible CauseA failure messageappears foll
Monitoring and Testing 4-163166-A2-GB20-10November 1998Remote Loopback TestsThe Remote Loopback tests enable you to troubleshoot your circuit by sendi
Monitoring and Testing 4-173166-A2-GB20-10November 1998Sending a Line Loopback Up or DownProcedureTo send a Line Loopback Up or Down sequence on the
Monitoring and Testing 4-183166-A2-GB20-10November 1998Sending a V.54/ANSI FT1 Activation/DeactivationProcedureTo send a V.54 or ANSI FT1 Activation
Monitoring and Testing 4-193166-A2-GB20-10November 1998Local Loopback TestsThe Local Loopback tests enable you to conduct circuit testing and fault is
Monitoring and Testing 4-203166-A2-GB20-10November 1998Starting a Line LoopbackThe Line Loopback command (LLB) loops the received signal on the networ
Monitoring and Testing 4-213166-A2-GB20-10November 1998Starting a Payload LoopbackThe Payload Loopback command (PLB) loops the received signal on the
Monitoring and Testing 4-223166-A2-GB20-10November 1998Starting a Repeater LoopbackThe Repeater Loopback command (RLB) loops the signal being sent to
Monitoring and Testing 4-233166-A2-GB20-10November 1998Starting a Data Channel LoopbackThe Data Channel Loopback command (DCLB) loops the data receive
Contents iii3166-A2-GB20-10November 19984 Monitoring and Testing Overview 4-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Monitoring and Testing 4-243166-A2-GB20-10November 1998Starting a Data Terminal LoopbackThe Data Terminal Loopback command (DTLB) loops the data recei
Monitoring and Testing 4-253166-A2-GB20-10November 1998Aborting LoopbacksThe Abort Loopback command stops all loopback tests or any selected loopbackt
Monitoring and Testing 4-263166-A2-GB20-10November 1998Test PatternsUse the Test Pattern commands to send, monitor, and abort test patterns.Available
Monitoring and Testing 4-273166-A2-GB20-10November 19985. From the Send screen, press the Function key that corresponds to theinterface for which you
Monitoring and Testing 4-283166-A2-GB20-10November 19983. From the Patterns screen, select Mon.F1Patterns:Abort Send MonF2F34. From the Patterns Mon s
Monitoring and Testing 4-293166-A2-GB20-10November 19983. From the Patterns screen, select Abort.F1Patterns:Abort Send MonF2F34. From the Patterns Abo
Monitoring and Testing 4-303166-A2-GB20-10November 1998Lamp TestUse the Lamp Test commands to start and stop a test of the DSU/CSU frontpanel LCD and
Monitoring and Testing 4-313166-A2-GB20-10November 19986. When you are satisfied that all LEDs are lighting and the LCD is functioningproperly, abort
Monitoring and Testing 4-323166-A2-GB20-10November 1998Displaying DSU/CSU Test StatusUse the Test Status command to display the active tests for the D
A-13166-A2-GB20-10November 1998SDCP MenuADSU ESFStat98-16084a-01DevHSSTest Perf TStat LED IDT1 Prt1Prt1UserTelcoCur24TotIntvlFarNearCur8TotIntvlTestR
Komentarze do niniejszej Instrukcji